Changzhou Wheat Automation эксплуатирует GMI, whatsapp: +8615951219765, другие модели D5281S и т. д. показаны в таблице ниже.

02. 06 , 2026
D1030S1 Ch; 1 + 1 Relay Output SPDT (Duplication or LD Alarm); Line Monitoring FunctionI, A, R, UL, FM, M22 
D1030D2 Ch; 2 Relay Outputs SPDT; Line Monitoring FunctionI, A, R, UL, FM, M22 
D1130S1 Ch; 1 + 1 Relay Output SPDT (Duplication or LD Alarm); Line Monitoring Function; AC PowerI, A, R, UL, FM, M22 
D1130D2 Ch; 2 Relay Outputs SPDT ; Line Monitoring Function; AC PowerI, A, R, UL, FM, M22 
D1030S-0181 Ch; 1 + 1 Relay Output SPDT (Duplication or LD Alarm); Line Monitoring Function; 10VDC PSI, A, R, UL, FM, M22 
D1030D-0182 Ch; 2 Relay Outputs SPDT; Line Monitoring Function; 10 VDC Power SupplyI, A, R, UL, FM, M22 
D1031D2 Ch; 2+2 OC Transistor Outputs (Duplication or LD Alarm); Line Monitoring Function; 1 KHz MaxI, A, R, UL, FM, M22 
D1031Q4 Ch; 4 OC Transistor Outputs; Line Monitoring Function; 1 KHz MaxI, A, R, UL, FM, M22 
D1032D2 Isolated Ch; 2+2 Relay Outputs SPST (Duplication or LD Alarm); Line Mon. Func.; SIL 2 (5yr)I,A,R,UL,FM,T,E,M22 
D1032Q4 Isolated Ch; 4 Relay Outputs SPST, Line Monitoring Function; SIL 2 (5yr)I,A,R,UL,FM,T,E,M22 
D1033D2 Isolated Ch; 2+2 OC Transistor Outputs (Duplication or LD Alarm); Line Mon. Func; SIL 2 (5yr)I,A,R,UL,FM,T,E,M22 
D1033Q4 Isolated Ch; 4 OC Transistor Outputs; Line Monitoring Function; SIL 2 (5yr)I,A,R,UL,FM,T,E,M22 
D1033D-0522 Iso. Ch; 2+2 OC Trans. Out (Dupl. or LD Alarm); Line Mon. Func; SIL 2 (5yr) Common NegativeI,A,R,UL,FM,T,E,M22 
D1033Q-0524 Isolated Ch; 4 OC Transistor Outputs; Line Monitoring Function, SIL 2 (5yr) Common NegativeI,A,R,UL,FM,T,E,M22 
D1033D-0582 Iso. Ch; 2+2 OC Trans. Out (Dupl. or LD Alarm); Line Mon. Func; SIL 2 (5yr) Common PositiveI,A,R,UL,FM,T,E,M22 
D1033Q-0584 Isolated Ch; 4 OC Transistor Outputs; Line Monitoring Function, SIL 2 (5yr) Common PositiveI,A,R,UL,FM,T,E,M22 
D1034S1 Ch; Trasparent to Contact-Proximity & Line Monitoring Function; SIL 3 (1 yr) / SIL 2 (10 yr)I,A,R,UL,FM,T,E,M22 
D1034D2 Isolat. Ch; Trasparent to Contact-Proximity & Line Monitoring Function; SIL 3 (1yr) / SIL 2 (10yr)I,A,R,UL,FM,T,E,M22 
D5000 Series
D5030S1 Ch; 1 SPDT Relay Output; Line Monitoring Function; SIL 3 (2 yr) / SIL 2 (20yr)I, A, T12 
D5030D2 Independent Ch; 2 SPST Relay Outputs; Line Monitoring Function; SIL 3 (2 yr) / SIL 2 (20yr)I, A, T12 

Unit is field configurable as Duplicator: 1 IN / 2 OUTs or 1 IN - 1+1 OUT (DI + LMF)


D5031S1 Ch; 1 NO/NC Solid State Output; Line Monitoring Function; SIL 3 (2 yr) / SIL 2 (20yr)I, A, T12 
       D5031D      2 Independent Ch; 2 NO/NC Transistor Out; Line Monitoring Function; SIL 3 (2 yr) / SIL 2 (20yr)I, A, T12 

Unit is field configurable as Duplicator: 1 IN / 2 OUTs or 1 IN - 1+1 OUT (DI + LMF)


D5231E8 Ch; NO/NC Solid State Output; Line Monitoring Function; SIL 2-22 
D5032S1 Ch; 1 SPDT Relay Output; Line Monitoring Function; SIL 3 (2 yr) / SIL 2 (20yr)I, A, T12 
D5032D2 Independent Ch; 2 SPST Relay Outputs; Line Monitoring Function; SIL 3 (2 yr) / SIL 2 (20yr)I, A, T12 

Unit is field configurable as Duplicator: 1 IN / 2 OUTs or 1 IN - 1+1 OUT (DI + LMF)


D5034S1 Ch; Trasparent to Contact-Proximity & Line Monitoring Function; SIL 3 (1 yr) / SIL 2 (10 yr)I, A, T12 
D5034D2 Independend Ch; Trasparent to Contact-Prox & Line Monitoring Function; SIL 3 (1 yr) / SIL 2 (10 yr)          I, A, T         12 
CertificationsI= IEC; A= ATEX; R= GOST; UL= Underwriter Laboratories; FM= Factory Mutual; T= TUV; E= Exida; M= Marine; Up to date info: www.gmintsrl.com
NotesSV = Special Version non stock delivery; D = Din Rail Mounting; DB = Power Bus Mounting; BR = Board Mounting;
SIL2, SIL3 according IEC61508 and IEC61511;   (yr) = Tproof Test Interval Time in Years. Size = Width in mm
Page # 4
Export Price List 2011                                               ( Rev. 0 dated December 23rd 2010 )
CodeDescriptionChCertificationsSize
DIGITAL OUTPUT  I.S. MODULES
D1000 Series
D1040Q4 Separated Channels;           1 + 1 + 1 + 1    72   mA Imax;  334 Ω; SIL 3 (LP) / SIL 2 (BS), A, R, UL, FM,E,M22 

2 + 2 Channels in parallel;     2 + 2                144   mA Imax;  167 Ω; SIL 3 (LP) / SIL 2 (BS), A, R, UL, FM,E,M22 

3 Channels in parallel;            1                       216   mA Imax;  111 Ω; SIL 3 (LP) / SIL 2 (BS), A, R, UL, FM,E,M22 

4 Channels in parallel;            1                       288   mA Imax;    84 Ω; SIL 3 (LP) / SIL 2 (BS), A, R, UL, FM,E,M22 
D1041Q4 Channels to drive LEDs;    1 + 1 + 1 + 1     49,6 mA Imax;  484 Ω; SIL 3 (LP) / SIL 2 (BS), A, R, UL, FM,E,M22 
D1042Q4 Separated Channels,          1 + 1 + 1 + 1      88,2 mA Imax; 273 Ω; SIL 3 (LP) / SIL 2 (BS), A, R, UL, FM,E,M22 

2 + 2 Channels in parallel,     2 + 2                 176,4 mA Imax; 137 Ω; SIL 3 (LP) / SIL 2 (BS), A, R, UL, FM,E,M22 

3 Channels in parallel,            1                       264,6 mA Imax;   91 Ω; SIL 3 (LP) / SIL 2 (BS), A, R, UL, FM,E,M22 

4 Channels in parallel,            1                       352,8 mA Imax;   68 Ω; SIL 3 (LP) / SIL 2 (BS), A, R, UL, FM,E,M22 
D1043Q4 Separated Channels,          1 + 1 + 1 + 1      49,6 mA Imax; 484 Ω; SIL 3 (LP) / SIL 2 (BS), A, R, UL, FM,E,M22 

2 + 2 Channels in parallel,     2 + 2                  99,2 mA Imax; 242 Ω; SIL 3 (LP) / SIL 2 (BS), A, R, UL, FM,E,M22 

3 Channels in parallel,            1                       148,8 mA Imax;  161 Ω; SIL 3 (LP) / SIL 2 (BS), A, R, UL, FM,E,M22 

4 Channels in parallel,            1                       198,4 mA Imax;  121 Ω; SIL 3 (LP) / SIL 2 (BS), A, R, UL, FM,E,M22 
D1045Y2 Channels for ATOS Valve                          177/199 mA Imax;  163 / 21 ΩI, A, FM22 
D1046Y2 Channels for WANDFLUH Valve                350 Imax; 121 ΩI, A, FM22 
D1047S1 Ch; ND Loads; Loop Powered; Line&Valve Monitoring Function; Selectable Ooutput; SIL 3 (1 yr)I, A, FM22 
D1048S1 Ch; NE Loads; Loop/Bus Powered; Line & Valve Monitoring Function; Selectable Output; SIL 3I, A, FM22 
D1049S1 Ch; ND Loads; Loop/Bus Powered; Line & Valve Monitoring Function; Selectable Output; SIL 3I, A, FM22 
D5000 Series
D5247S1 Ch; Redund. (1oo2) Solenoid Driver; Loop Powered; Transparent Line & Load Alarm Fnct; SIL 3-22 

Unit has three field selectable Valve power Outputs; Both Open and Short Circuit Fault Detection


D5048S1 Ch; Solenoid Driver; Loop Powered; Transparent Line & Load Alarm Function; SIL 3 (20 yr)I, A, T12 

Unit has three field selectable Valve power Outputs; Both Open and Short Circuit Fault Detection


D5049S1 Ch; Solenoid Driver; Bus Powered; Transparent Line & Load Alarm Function; SIL 3 (1 Yr)I, A, T12 

Unit has three field selectable Valve power Outputs; Both Open and Short Circuit Fault Detection


DIGITAL OUTPUT / RELAY  OUTPUT  I.S. MODULES
D1000 Series
D1044S1 Channel;                              1 SPDT Relay Output to Hazardous LocationI, A, FM22 
D1044D2 Channel;                              2 SPDT Relay Outputs to Hazardous LocationI, A, FM22 
DIGITAL OUTPUT / HIGH POWER NON I.S. MODULES
D1000 Series
D1098S1 Ch; 24 Vdc 12 W Digital Output Isolated Module; Output for NE Load; SIL 3 (3Yr)Not Applicable22 

With Line and Load Short and Breakage Diagnostic Detection


D1099S1 Ch; 24 Vdc 12 W Digital Output Isolated Module; Output for ND Load; SIL 3 (3Yr)Not Applicable22 

With Line and Load Short and Breakage Diagnostic Detection


D5000 Series
D5280S1 Ch; Solenoid Driver; Loop Powered; Transparent Line & Load Alarm Function; SIL 3Not Applicable22 

24V, 500 mA - 12 Watts Power Output; Both Open and Short Circuit Fault Detection


D5281S1 Ch; (1oo2) Solenoid Driver; Loop Powered; Transparent Line & Load Alarm Function; SIL 3Not Applicable22 

24V, 500 mA - 12 Watts Power Output; Both Open and Short Circuit Fault Detection


CertificationsI= IEC; A= ATEX; R= GOST; UL= Underwriter Laboratories; FM= Factory Mutual; T= TUV; E= Exida; M= Marine; Up to date info: www.gmintsrl.com