Changzhou Wheat Automation эксплуатирует GMI, whatsapp: +8615951219765, другие модели D1091S и т. д. показаны в таблице ниже.

02. 06 , 2026
D1080D2 Ch; Relay Output SPDT; Suitable for 3 Wire probesI, A, R, M22 
D1081D2 Ch; O.C. Transistor Outputs; Suitable for for 3 Wire probesI, A, R, M22 
D1180D2 Ch; Relay Output SPDT; Suitable for for 3 Wire probes; AC Power SupplyI, A, R, M22 
POWER SUPPLY MODULES
D1000 Series
PSD1000Zone 2 Power Supply; II 3 G EEx nA IIC T4; 24 V - 0,6 A Output; For AC power of D1000 ModulesA, FM, M22 
PSD1000/FZone 2 PS; II 3 G EEx nA IIC T4; 24 V - 0,6 A Output; For AC power of D1000 Modules with AlarmA, FM, M22 
PSD1001I.S. Power Supply; [EEx ia] IIC; 4 Parallelable Outputs each with 15 V - 20 mA; SIL 3 (LP)I,A,R,UL,FM,E,M22 
PSD1001CI.S. Power Supply; [EEx ia] IIB; 10 V -150 mA Output ; SIL 3 (LP)I,A,R,UL,FM,E,M22 
PSU1003I.S. Power Supply  Component; EEx ia IIB T4; 5 V - 160 mA OutputA22 
PSD1004I.S. Power Supply; EEx ia IIB; 5 V -160 mA Output;A, M22 
PSD1200 Series
PSD1210Zone 2 Power Supply; II 3 G EEx nA IIC T4; 24 V - 10 A Output; SIL 3 (N+ 1/ 3 yr) / SIL 2 (10 yr)A, FM, E200 
I.S. DISPLAY  MODULES
T3000 Series
T3010S4-20 mA Intrinsically Safe 4.5 digit Indicator; Loop Powered; IP 65; Size 144x144x50 mm;A-R-FM139 

20 mm high Display; Suitable for Wall Mounting; Flush or Pipe mounting using OPT 3092-93


OPT3092Stainless Steel Bracket set and Gasket for Flush-Panel Mounting
Not Applicable-
OPT3093Stainless Steel Bracket set for 50-70 mm Pipe Mounting & SS set for Flush-Panel Mounting
Not Applicable-
CertificationsI= IEC; A= ATEX; R= GOST; UL= Underwriter Laboratories; FM= Factory Mutual; T= TUV; E= Exida; M= Marine; Up to date info: www.gmintsrl.com
NotesSV = Special Version non stock delivery; D = Din Rail Mounting; PA: Panel Mounting; FL: Flush Mounting; PO: Pole Mounting
SIL2, SIL3 according IEC61508 and IEC61511;   (yr) = Tproof Test Interval Time in Years. Size = Width in mm
Page # 7
Export Price List 2011                                               ( Rev. 0 dated December 23rd 2010 )
CodeDescriptionChCertificationsSize
SIL 3 RELAY MODULES
D1000 Series
D1092S1 Ch; SIL3 Relay; Out: N° 2 SPST NO Relay (1 for NE Loads & 1 for ND Loads); SIL 3 (20Yr)T, FM22 
D1092S-0691 Ch; SIL3 Relay; Out: N° 2 SPST NO/NC Relay (1 for NE Loads & 1 for ND Loads); SIL 3 (20Yr)T, FM22 
D1092D2 Ch; SIL 3 Relay; Out: N° 4 SPST NO Relay (2 for NE Loads & 2 for ND Loads); SIL 3 (20Yr)T, FM22 
D1092D-0692 Ch; SIL 3 Relay; Out: N° 4 SPST NO/NC Relay (2 for NE Loads & 2 for ND Loads); SIL 3 (20Yr)T, FM22 
D1093S1 Ch; SIL3 Relay; Out: N° 2 SPST NO Relay (1 for NE Loads & 1 for ND Loads); SIL 3 (20Yr)T, FM22 

With Line and Load Breakage Detection


D5000 Series
D5090S1 Ch; SIL3 Relay for NE Load; SPDT NC 4 Amps OUT plus Service OUT; SIL 3 (10Yr) / SIL 2 (20yr)T12 

Safty Function is De-energized Relay / De-energized Load


D5290S1 Ch; SIL3 Relay for NE Load; SPDT NC 10 Amps OUT plus Service OUT; SIL 3 (10Yr) / SIL 2 (20yr)T22 

Safety Function is De-energized Relay / De-energized Load


D5290S-0781 Ch; SIL3 Relay for NE Load; 2 NC 3 Amps OUT plus Service OUT; SIL 3 (10Yr) / SIL 2 (20yr)T22 

Safety Function is De-energized Relay / De-energized Load


D5290S-0791 Ch; SIL3 Relay for NE Load; 2 NC 4 Amps OUT / 110Vac Coil ; SIL 3 (10Yr) / SIL 2 (20yr)T22 

Safety Function is De-energized Relay / De-energized Load


D5091S1 Ch; SIL3 Relay for ND Load; SPDT NO 4 Amps OUT plus Service OUT; SIL 3 (6Yr) / SIL 2 (20yr)T12 

Unit is also SIL 3 for ND Load; SPDT NC 4 Amps OUT plus Service OUT; SIL 3 (10Yr) / SIL 2 (20yr)



Safety Function is Energized Relay / Energized Load or De-energized Realy / Energized Load


D5291S1 Ch; SIL3 Relay for ND Load; SPDT NO 10 Amps OUT plus Service OUT; SIL 3 (6Yr) / SIL 2 (20yr)T22 

Unit is also SIL 3 for ND Load; SPDT NC 10 Amps OUT plus Service OUT; SIL 3 (10Yr) / SIL 2 (20yr)



Safety Function is Energized Relay / Energized Load or De-energized Realy / Energized Load


D5293S1 Ch; SIL3 Relay for NE Load; SPST NC 10 Amps OUT plus Fault OUT; SIL 3 (10Yr) / SIL 2 (20yr)-22 

With Line-Load Open and Short Circuit, Loss of Power, Hearth Leackage Detection; RS485 OUT



Safety Function is De-energized Relay / De-energized Load


D5294S1 Ch; SIL2 Relay for ND Load; 2 x SPST NO 10 Amps OUT plus Fault OUT; SIL 3 (7Yr) / SIL 2 (20yr)-22 

With Line-Load Open and Short Circuit, Loss of Power, Hearth Leackage Detection; RS485 OUT



Safety Function is De-energized Relay / De-energized Load; 2+2 relay blocks for increased availability

CertificationsI= IEC; A= ATEX; R= GOST; UL= Underwriter Laboratories; FM= Factory Mutual; T= TUV; E= Exida; M= Marine; Up to date info: www.gmintsrl.com
NotesD = Din Rail Mounting; BR = Board Mounting; NA = Not Available
SIL2, SIL3 according IEC61508 and IEC61511;   (yr) = Tproof Test Interval Time in Years. Size = Width in mm
Page # 8
Export Price List 2011                                               ( Rev. 0 dated December 23rd 2010 )
CodeDescriptionChCertificationsSize
OPTIONS & ACCESSORIES
D1000 Series
BUSExtra Price for Power Bus Housing; Add: " /B " to model number
Not Applicable22 
OPT1096Kit For Bus Mounting Include: N° 2 MOR016, N° 1 MOR017, N° 1 MOR022, N° 2 MCHP065
Not Applicable-

One needed for each group of modules.


MOR 010Grey Terminal Block Laser Engraved: 1-2-3-4
Not Applicable22 
MOR 016Din Rail Stopper
Not Applicable
MOR 015Plug-in terminal block male, vertical out, for Power Bus
Not Applicable
MOR 017Plug-in terminal block male, horizontal out, for Power Bus
Not Applicable
MOR 022Plug-in terminal block female, horizontal out, for Power Bus
Not Applicable
MOR 046/2Terminal Block for APN005: Passive output for D1052* / D1053* / D1072* (1 each channel)
Not Applicable
MOR 058Terminal Block for PLC Pulse Damping of D109X relay
Not Applicable
MCHP 065Din Rail Anchor for terminal block side of the Power Bus
Not Applicable
PPC1090Pocket Portable Configurator required to configure programmable units
Not Applicable
PPC1092PC Adapter required to configure via PC programmable units; Include CABF010 & USB Adapter
Not Applicable
SWC1090Software for modules configuration via PPC1092; Available on our web site free of charge
Not Applicable-
CABF010Sub D 9 Poles Female-Female Nul-Modem; 1800 mm lenght
Not Applicable-
USB adapterUSB to serial line RS-232  Adapter;
Not Applicable-
OPT1091Cold Junction Compensator to be ordered for THCs Inputs; One required for each input
Not Applicable-
VExtra Price for Channel configuration according to Customer Specs.
Not Applicable-
MCHP 064Tagplate in policarbonate material
Not Applicable22 
MCHP 09072 mylar white lables for tagging (A4); Software for compilation on our web site free of charge
Not Applicable-
MCHP 1395 mm Spacer for spacing of modules on custom boards PBCO series.
Not Applicable
MCHP  061/3Dummy Bus module with Bus connector removed
Not Applicable22 
D1000DDummy module to be used with custom boards PBCO series
Not Applicable22 
D1091SCommon Allarm Module for D1000 Series with Fault Output, 1 SPDT  Relay OutputNot Applicable22 
D1002SRedundant Power Connection & Common Alarm Module (SPST) for D1000 Series; Max 4 AmpNot Applicable22 
CABF02530 cm flat cable to interconnect two PBCO-16-037 Boards
Not Applicable-
D1000R19" Rack unit, 3 units High, suitable for 16 D1000 series modules
Not Applicable